Configuration
CPU 317T: Technology Functions
A5E00251798-03
4-33
4.5.2 Configuration - Axis
The Axis > Configuration dialog box shows the axis and drive settings.
To edit these settings, click "Configure active data record".
This dialog box also contains functions for managing data records and data record
changeover. For technology objects supporting several data records, you can:
create new data records,
delete data records,
define which data record for the technology object is loaded at CPU startup,
and
reconfigure the selected data record.