Connect-tech CANpro/104-Plus Instrukcja Użytkownika Strona 12

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 22
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 11
CANpro/104-Plus Opto User Manual
CTIM-00052 Revision 0.00 4/23/2009 www.connecttech.com 12
800-426-8979 | 519-836-1291
Software Configuration
The information provided below is intended for advanced users and developers that wish to create their own
custom drivers. Typical CANpro/104-Plus Opto users will used the driver provided by Connect Tech.
PCI Properties of CANpro/104-Plus Opto
The CANpro/104-Plus Opto card will appear in your system with the following PCI information:
Vender ID: 0x10b5
Device ID: 0x9030
SubVender ID: 0x12c4
SubVender Device ID: 0x900
CAN Controller Address Space
CAN controllers are mapped on the PLX 9030 PCI Base Address 2 (BAR2) to Local Address Space 0. This
address space is re-mapped to a local offset of 0x00. Each CAN controller is allotted 256 bytes of address
space. CAN controller #1 has a local address range of 0x000 - 0x0FF, while CAN controller #2 has a local
address range 0x100 0x1FF. See below for the full address/register allocation details in both BasicCAN and
PeliCAN modes.